【New Release】 Anaerobic reaction biodegrader CH1200


Brand: Thmorgan

Model: CH1200

 

one.Instrument use:

1. Used for anaerobic reaction biodegradation experimental research;

2. For the detection of biodegradation rate of biobased anaerobic reaction;

3. For renewable bioenergy research;

4. Used for anaerobic reaction biodegradation process analysis;

 

Second, product characteristics

1. Nitrogen generator supply nitrogen;

2. The design method of solid culture and open gas supply is adopted;

3. High detection accuracy,12 independent methane detection, real-time online measurement of methane release;

4. Dual display of methane concentration and accumulation, which can be derived in the form of charts or curves;

5. Wide detection range, the highest detection limit can reach 10000ppm;

6. Quiet design,12 independent controllable gas supply, sound less than 45db;

7. Automatic mixing, automatic water, automatic control;

8. Double-layer reactor design, more conducive to gas supply and humidity regulation;

9. Cloud platform detection, real-time online observation of data and curves.

 

Second, product principle:

Bio-based materials are metabolized by anaerobic microorganisms under appropriate temperature and humidity under anaerobic conditions, resulting in anaerobic biodegradation of samples to produce methane and other final products. The ratio of methane generation to theoretical generation through whole-process detection is the biodegradation rate of anaerobic reaction.

Three, technical parameters:

1. Working conditions:

1.1 Power supply voltage: AC 220V±10% 50Hz;

1.2 Working temperature: 15 ~ 30℃;

1.3 Relative humidity: ≤ 80%;

 

2. Air supply system

2.1 Gas supply mode: Nitrogen generator to supply 99.9% pure nitrogen;

2.2 Air pump control: the air pump is divided into 12 channels, each channel has an independent switch;

2.3 Electronic flowmeter adjustment range: 0.01-500ml /min;

2.4 Adjustment range of glass rotameter: 50-300mL /min;

2.5 With 12 glass rotameters to adjust the flow rate;

2.6 With 12 electronic flowmeters to collect flow rate;

 

3. Temperature control system:

3.1 Temperature control mode: air bath;

3.2 Set temperature range: room temperature -90 ℃, step by 0.1℃;

3.3 Temperature control accuracy :≤±0.1℃;

3.4 Temperature control box top sliding door, easy to operate;

 

4. Reactor system:

4.1 Number of channels :12;

4.2 Reactor volume :2000ml;

4.3 Reactor design: double-layer design;

4.4 Water adding mode: automatic water adding;

4.5 Mixing method: automatic mixing;

4.6 Mixing shaft design: mixing down;

4.7 Gas supply mode: bottom gas supply;

5. Test the system

5.1 Detection method: methane probe to detect methane;

5.2 Number of methane probes :12;

5.3 Display mode: synchronous dual display of methane concentration and total quantity;

5.4 Detection range :0-10000ppm;

5.5 Resolution :1ppm;

5.6 Data collection cycle: up to 1 second once, seconds, minutes, hours can be freely selected;

5.7 Probe dehumidification protection system: Yes;

 

6. Software system

6.1 Software control system with independent intellectual property rights;

6.2 Software can collect data and generate real-time data curve;

6.3 Bearer system: professional operating system such as win7/8/10;

6.4 Data storage: It can be stored in real time in the experiment;

6.5 With a cloud platform, data can be accessed remotely;

 

five. Instrument configuration requirements

Serial number

name

quantity

unit

remark

 

1

Host machine

1

Taiwan

 

 

2

Reaction flask

12

a

 

 

3

Decarburization bottle

12

a

 

 

4

Condensing bottle

12

a

 

 

5

Dehumidifier bottle

12

a

 

 

6

Connecting hose

1

Set of

 

 

7

software

1

Set of

 

 

8

Random file

1

Set of