I. Product Applications
1. Meets the testing standards specified in GB/T 19276.2-2003;
2. Meets the testing standards specified in GB/T 33616-2017;
3. Meets the testing requirements of GB/T 40612-2021;
4. Meets the testing requirements of GB/T 40367-2021;
5. Meets the testing standards specified in ISO 14852:1999;
6. Meets the testing standards specified in ISO 19679:2020;
7. Can be used for biodegradation testing in the activated sludge process;
8. Can be used for bio-based biodegradability testing;
II. Product Features
1. Fully complies with the testing requirements of GB/T 19276.2;
2. Up to 12 channels can be used simultaneously for biodegradability testing;
3. Online measurement of carbon dioxide concentration and total amount;
4. Displays both carbon dioxide concentration and cumulative total, with the option to export data in chart format;
5. A water-based cultivation and open‑oxygen‑supply design is adopted to simulate a highly aerobic environment.
6. Air bath temperature control with a temperature regulation accuracy of ±0.1℃;
7. Magnetic stirring system, providing long-term stirring;
8. Cloud-platform monitoring allows real-time online observation of data and trend curves.
III. Product Principle
This experimental system simulates the biodegradation of bio-based materials under aerobic hydroponic conditions. In an aerobic hydroponic environment, microorganisms utilize the bio-based material as a carbon source, consuming oxygen and producing inorganic compounds such as carbon dioxide and water. The concentration of carbon dioxide is monitored in real time using a high-precision infrared sensor, and by integrating the measured CO₂ concentration with flow rate and time, the total amount of CO₂ released during the sample’s biodegradation can be calculated. The ratio of the experimentally determined CO₂ release to the theoretical CO₂ release serves as the biodegradation rate.

IV. Product Specifications
1. Working conditions :
1.1 Power supply voltage: AC, 220 V ±10%, 50 Hz, single-phase;
1.2 Operating temperature: 15–30°C;
1.3 Relative humidity: ≤80%;
1.4 Instrument operational durability: capable of continuous operation over extended periods;
1.5 Maximum power: 5 kW;
1.6 Overall dimensions (L×W×H): 2000 mm × 900 mm × 1600 mm;
1.7 Gross weight: 550 kg;
2. Oxygen Supply System:
2.1 Aeration method: continuous aeration for oxygen supply, with a built-in air pump;
2.2 Air Pump Control: The air pump is divided into 12 channels;
2.3 Flow control method: PLC control; flow rate is automatically adjusted according to the setpoint.
2.4 Flow control accuracy: ±1%;
2.5 Flow measurement method: Real-time acquisition using an electronic flow meter;
2.6 Flow rate measurement range: 0–300 mL/min;
2.7 Equipped with 12 electronic flow meters for flow measurement;
2.8 Traffic control and traffic collection operate independently;
3. Temperature Control System:
3.1 Temperature control method: air bath;
3.2 Temperature range setting: room temperature to 90℃, with a step size of 0.1℃;
3.3 Temperature Control Accuracy: ≤±0.1℃;
4. Reaction System:
4.1 Number of Channels: ≥12;
4.2 Mixing Method: 12-channel magnetic stirring;
4.3 Reaction mode: liquid-phase reaction;
4.4 Reaction vessel volume: 500 mL;
4.5 Decarbonization system: Yes;
4.6 Condensation system: Yes;

5. Condensation dehumidification System:
5.1 System Composition: low-temperature constant-temperature bath, fully automatic condenser flask, and dehumidification flask;
5.2 Channel Configuration: Each channel is equipped with a condensation bottle and a desiccant bottle.
5.3 Condensation Method: The condenser is equipped with a water bath for condensation.
5.4 Condensing Temperature: The condensing temperature can be as low as -4°C;
5.5 Drainage Method: Condensate water can be automatically discharged on a timed basis;
5.6 Dehumidification method: The dehumidification bottle features a double-layer design;
5.7 Connection Method: The condenser flask and the dehumidifier flask are connected in series;
6 . Detection system:
6.1 Detection method: Carbon dioxide is detected using an infrared sensor, while oxygen is measured with an oxygen sensor.
6.2 Number of probes: 1 infrared probe, 1 oxygen sensor;
6.3 Display Mode: Simultaneous dual display of concentration and total amount;
6.4 Detection range: Carbon dioxide 0–5000 ppm, Oxygen 0-21.0% ;
6.5 Resolution: Carbon dioxide 1 ppm, oxygen 0.1% ;
6.6 Data Acquisition Cycle: 5 minutes;
6.7 Probe dehumidification protection system: Yes;
6.8 Gas chromatograph: can be used in conjunction;
6.9 Anaerobic Biodegradation Test: Can be conducted;
7. Software Control System:
7.1 Software control system with independent intellectual property rights;
7.2 The software collects data and can generate real-time data curves.
7.3 Host System: Professional editions of Windows 7, 8, 10, etc.;
7.4 Data Storage Method: Real-time storage is supported during the experiment.
7.5 Equipped with a cloud platform, enabling remote access to data;
7.6 Operational Durability: Capable of continuous operation for more than 6 months.
V. Product Configuration
|
Serial number |
Name |
Quantity |
Unit |
Note |
|
1 |
Host |
1 |
Taiwan |
|
|
2 |
Reaction vessel |
12 |
one |
|
|
3 |
Decarbonization System |
1 |
set |
|
|
4 |
Condenser flask |
12 |
one |
|
|
5 |
Low-temperature constant-temperature bath |
1 |
set |
|
|
6 |
Dehumidifier bottle |
12 |
one |
|
|
7 |
Connecting hose |
1 |
set |
|
|
8 |
Software |
1 |
set |
|
|
9 |
Random file |
1 |
set |
|