Product
Nucleic Acid Extraction and Fluorescent Quantitative Integrated Instrument
One . Product Uses
1. Integrated nucleic acid extraction and fluorescent quantitative PCR analysis for various viruses, with fully automated operation throughout the entire workflow and no manual intervention required;
2. It can automatically perform nucleic acid extraction and qPCR detection on human blood, body fluids, hair, muscle, and other samples.
3. It can automatically perform nucleic acid extraction and qPCR analysis on samples such as animal and plant tissues, microorganisms, and cells.
4. Suitable for gene expression studies: quantitative and qualitative gene expression analysis, SNP genotyping, microRNA analysis, methylation analysis, and more;
5. Suitable for melting curve analysis;
6. Suitable for high-throughput sample screening;
Two , Product Features
1. Integrated design: a single unit can automatically perform nucleic acid extraction, qPCR detection, and report generation. qPCR report;
2. Highly automated end-to-end workflow: From nucleic acid extraction and qPCR detection to report generation, the entire process is fully automated with no manual intervention required.
3. The entire system operates in a closed-loop configuration, ensuring zero contact between laboratory personnel and samples for safe handling.
4. High throughput: capable of processing 1–96 samples at a time;
5. The magnetic-bead-based nucleic acid extraction method offers high efficiency and stable purity.
6. The qPCR detection module features six-color fluorescence detection channels and high detection sensitivity;
7. High efficiency: Sample testing can be completed in just 2 hours;
8. High adaptability: accommodates various types of samples and tests;
9. Implement zoning design, UV sterilization, HEPA filtration, and other measures to minimize contamination to the greatest extent possible;
III. Operating Principle:
The instrument comprises five modules: a fully automated nucleic acid extraction module, an automated liquid-handling module, an automated sealing module, a qPCR detection module, and a report-output module. It employs a magnetic-bead-based method for fully automated nucleic acid extraction; the extracted nucleic acid samples are then transferred to reaction tubes via the automated liquid-handling module and mixed with pre-loaded assay reagents to establish the PCR reaction mix. The automated sealing module subsequently seals the PCR plates, after which the qPCR detection module automatically performs PCR amplification and fluorescence signal detection. Finally, a qPCR test report is automatically generated and output.

IV. Technical Parameters
( One ) Whole-machine system
1. Whole-system configuration: comprising a nucleic acid extraction module, an automated liquid-handling module, and a sealing module, The qPCR detection module and the report output module consist of five parts;
2. Control System: Built-in touch display;
3. Data Interface: Two USB ports;
4. External dimensions: 120 cm (W) × 65 cm (D) × 95 cm (H);
5. Voltage: 220V, 50Hz;
6. Operating temperature: 15–30°C;
7. Open consumables design: compatible with standard consumables;
( Two ) Nucleic acid Extract module
1. Extraction principle: magnetic bead method;
2. Sample size: 1–96;

3. Single sample volume: 20–1000 μL;
4. Magnetic bead recovery rate: ≥99%;
5. Pore-to-pore uniformity: CV ≤ 1%;
6. Anti-pollution design: zonal design + Ultraviolet sterilization +HEPA filtration ;
7. Module configuration: adopts a rotary design;
(3) Automated Pipetting Module
1. Pipetting range: 2–100 μl;
2. Pipetting Performance: Accuracy ≤1%, repeatability CV ≤1%;
3. Pipetting Channel: 8-channel pipetting unit;
4. Work envelope: The robotic arm supports flexible multi-axis motion in vertical, front-to-back, and left-to-right directions, with precise and reliable positioning, ensuring full coverage of the operational workspace.
(4) PCR Plate Sealing Module
1. Laminating principle: roller-press type;
2. Film-sealing method: pressure-sensitive adhesive;
3. Film material: high-transmittance optical fluorescence detection-grade film;
4. Sealing time: 8 s;
5. The film-sealing run track shares the same running track as the qPCR detection run track;
(5) qPCR detection module
1. PCR reaction volume: 20–100 µL;
2. Sample capacity: 96 × 0.2 ml;
3. Sample repeatability: CV ≤ 1%;
4. Detection channels: 6 channels;
5. Compatible dyes: FAM, HEX, ROX, Cy5, TAMRA, and Quasar 705;
6. Excitation Light Source: Long Lifespan, High Power LED light (full spectrum);
7. Temperature range: 4°C–100°C (with automatic pressure regulation via the heated lid);
8. Heating rate: 4.0°C/s;
9. Cooling rate: 4.0°C/s;
10. Temperature accuracy: ±0.1℃;
11. Temperature uniformity: ±0.2°C.

V. Configuration
|
Serial Number |
Name |
Quantity |
Unit |
|
1 |
Nucleic Acid Extraction Module |
1 |
set |
|
2 |
Automatic Pipetting Module |
1 |
set |
|
3 |
PCR plate Sealing Module |
1 |
set |
|
4 |
qPCR detection module |
1 |
set |
|
5 |
Report Output Module |
1 |
set |
|
6 |
Software |
1 |
set |