Product
All categories
Composting infrared biodegrader
Model: M2400 PLUS
First, the use of the product
1. Meet the testing requirements of GB/T19277.1-2011 standard;
2. Meet the testing requirements of ISO14855.1 standard;
3. Meet the testing requirements of JIS K 6953-1 standard;
4. Applicable to external testing by the Quality Inspection Institute;
5. Applicable to external testing services of third-party institutions;
6. It is suitable for self-inspection and formula optimization of bio-based material manufacturers;
7. Suitable for basic research on biodegradation;
Second, product features
1. Fully meet the testing requirements of GB/T 19277.1-2011 standard;
2. High throughput, up to 24 channels can be used for biodegradability detection at the same time;
3. On-line determination of carbon dioxide and methane concentration and total amount, which can be exported in the form of charts;
4. Wide detection range, the highest detection limit can reach 10000ppm;
5. Adopt the design method of solid culture and open oxygen supply to simulate the environment of strong aerobic demand;
6. Automatic stirring, automatic water addition, automatic drainage, air bath temperature control;
7. Cloud platform detection, online observation of data and curves;
Third, the principle of the product
This experimental system simulates the biodegradation of bio-based materials under aerobic composting conditions. In an aerobic environment, microorganisms use bio-based materials as carbon sources to consume oxygen and produce inorganic substances such as carbon dioxide and water, and the carbon dioxide generated is monitored in real time by high-precision infrared sensors, and the real-time concentration of carbon dioxide detected is integrated with flow rate and time, and the carbon dioxide release of sample biodegradation can be calculated. The biodegradation rate is the percentage of the biodegradable CO2 release of the sample to its theoretical CO2 release.

Fourth, technical parameters
1. Working conditions:
1.1 Power supply voltage: AC 220V±10% 50Hz single phase;
1.2 Working temperature: 15~30°C;
1.3 Relative humidity: ≤80%;
1.4 Durability of instrument operation: it can work continuously for a long time;
1.5 Power: 7KW;
1.6 Appearance size (L×W×H): 3500mm×900mm×1600mm;
1.7 Gross weight: 1000KG;
2. Oxygen supply system:
2.1 Pre-decarbonization system: Yes;
2.2 Air supply mode: continuous aeration and oxygen supply, built-in air supply pump;
2.3 Air pump control: The air pump is divided into 24 channels, and each channel is independently controlled;
2.4 Flow control mode: PLC control, the flow rate can be automatically adjusted according to the set value;
2.5 Flow control accuracy: ±1%;
2.6 Flow collection method: real-time collection of electronic flow meter;
2.7 Flow collection range: 0-500ml/min;
2.8 It has 24 electronic flowmeters to collect the flow rate;
2.9 Flow control and traffic collection operate independently;
3. Temperature control system:
3.1 Temperature control method: air bath;
3.2 Set temperature range: room temperature -90°C, step 0.1°C;
3.3 Temperature control accuracy: ≤±0.1°C;
4. Reactor system:
4.1 Number of channels: ≥24;
4.2 Reactor volume: ≥2000ml;
4.3 Reactor design: double-layer design;
4.4 Water addition method: automatic water addition;
4.5 Stirring method: automatic stirring;
4.6 Stirring shaft design: lower stirring;
4.7 Gas supply mode: bottom gas supply;

5.Condensation dehumidification system:
5.1 System composition: low-temperature thermostatic bath, automatic condensation bottle and dehumidification bottle;
5.2 Channel composition: each channel comes with its own condensation bottle and dehumidification bottle;
5.3 Condensation method: The condensing bottle is condensed by water bath;
5.4 Condensing temperature: The condensing temperature can be as low as -4°C;
5.5 Drainage method: condensate can be automatically discharged at regular intervals;
5.6 Dehumidification method: The dehumidification bottle adopts a double-layer design;
5.7 Connection: The condensing bottle and the dehumidification bottle are designed in series;
6. Detection system:
6.1 Detection method: infrared probe to detect carbon dioxide, methane probe to detect methane;
6.2 Number of probes: 2 infrared probes, 2 methane probes;
6.3 Display mode: carbon dioxide concentration and methane concentration are displayed simultaneously;
6.4 Detection range: carbon dioxide 0-10000ppm, methane 0-5000ppm;
6.5 Resolution: 1ppm;
6.6 Data acquisition cycle: 5min;
6.7 Probe dehumidification protection system: Yes;
6.8 Temperament analyzer: can be used in combination;
6.9 Anaerobic biodegradation experiment: can be done;
7. Software System:
7.1 Software control system with independent intellectual property rights;
7.2 The software collects data and generates real-time data curves;
7.3 Bearing system: win7/8/10 and other professional operating systems;
7.4 Data storage mode: real-time storage during the experiment;
7.5 It has a cloud platform and can remotely access data.
7.6 Durability: It can work continuously for more than 6 months for a long time;

5. Standard configuration
|
serial number |
name |
quantity |
unit |
remark |
|
1 |
host |
1 |
platform |
|
|
2 |
Reaction flasks |
24 |
piece |
|
|
3 |
Decarburization devices |
1 |
cover |
|
|
4 |
Condensing bottles |
24 |
piece |
|
|
5 |
Cryogenic thermostat |
1 |
cover |
|
|
6 |
Dehumidifying bottles |
24 |
piece |
|
|
7 |
Connect the hose |
1 |
cover |
|
|
8 |
Software |
1 |
cover |
|
|
9 |
Random files |
1 |
cover |
|