Product


Hydroponic infrared biodegradation instrument

Hydroponic infrared biodegradation instrument

Brand: Thmorgan
Model: T1200 PLUS

I. Product Use

1. Meets the detection standards of GB/T19276.2-2003;

2. Meets the detection standards of GB/T33616-2017;

3. Meets the detection requirements of GB/T40612-2021;

4. Meets the detection requirements of GB/T40367-2021;

5. Meets the detection standards of ISO14852-1999;

6. Meets the detection standards of ISO19679-2020;

7. Can be used for activated sludge biodegradation testing;

8. Can be used for bio-based biodegradability testing;

II. Product Features

1. Fully meets the detection requirements of GB/T 19276.2 standard;

2. Up to 12 channels can be used simultaneously for biodegradability testing;

3. Online determination of carbon dioxide and methane concentration and total amount;

4. Dual display of carbon dioxide and methane concentration and cumulative amount, which can be exported in the form of charts;

5. Using an aqueous culture and open oxygen supply design method to simulate a strongly aerobic environment;

6. Air bath temperature control, temperature control accuracy ±0.1℃;

7. Magnetic stirring system, providing long-time stirring;

8. Cloud platform detection, real-time online observation of data and curves;

III. Product Principle

This experimental system simulates the biodegradation process of bio-based materials under aerobic hydroponic conditions. In an aerobic hydroponic environment, microorganisms use bio-based materials as a carbon source, consume oxygen, and produce inorganic substances such as carbon dioxide and water. The generated carbon dioxide is monitored in real-time for its concentration using a high-precision infrared sensor. By integrating the detected real-time carbon dioxide concentration with flow rate and time, the amount of carbon dioxide released from the sample biodegradation can be calculated. The percentage of the sample biodegradation's carbon dioxide release to its theoretical carbon dioxide release is the biodegradation rate.

 

 

IV. Product Parameters
1. Operating Conditions

1.1 Power voltage: AC, 220V±10%, 50Hz, single-phase;

1.2 Operating temperature: 15~30℃;

1.3 Relative humidity: ≤80%;

1.4 Instrument operation durability: Can work continuously for a long time;

1.5 Maximum power: 5KW;

1.6 External dimensions (L×W×H): 2000mm ×900mm ×1600mm;

1.7 Gross weight: 550KG;

2. Oxygen Supply System:

2.1 Air supply method: Continuous aeration oxygen supply, built-in air pump;

2.2 Air pump control: The air pump is divided into 12 channels;

2.3 Flow control method: PLC control, the flow rate can be automatically adjusted according to the set value;

2.4 Flow control accuracy: ±1%;

2.5 Flow acquisition method: Real-time acquisition by electronic flow meter;

2.6 Flow acquisition range: 0-300ml/min;

2.7 Has 12 electronic flow meters to collect flow rate;

2.8 Flow control and flow acquisition operate independently;

3. Temperature Control System:

3.1 Temperature control method: Air bath;

3.2 Set temperature range: Room temperature - 90℃, step 0.1℃;

3.3 Temperature control accuracy: ≤±0.1℃;

4. Reaction System:

4.1 Number of channels: ≥12;

4.2 Stirring method: 12-channel magnetic stirring;

4.3 Reaction method: Liquid reaction;

4.4 Reaction bottle volume: 500ml;

4.5 Decarbonation system: Yes;

4.6 Condensation system: Yes;

5. Condensation dehumidification System:

5.1 System composition: Low-temperature thermostat, fully automatic condensation bottle and dehumidification bottle;

5.2 Channel composition: Each channel has its own condensation bottle and dehumidification bottle;

5.3 Condensation method: Water bath condensation is used for the condensation bottle;

5.4 Condensation temperature: The condensation temperature can be as low as -4℃;

5.5 Drainage method: Condensation water can be automatically drained at regular intervals;

5.6 Dehumidification method: The dehumidification bottle adopts a double-layer design;

5.7 Connection method: The condensation bottle and dehumidification bottle are connected in series;

6 .Detection System:

6.1 Detection method: Infrared probe detects carbon dioxide, methane probe detects methane;

6.2 Number of probes: Infrared probes 1 methane probe;

6.3 Display: Simultaneous dual display of carbon dioxide and methane concentrations;

6.4 Detection range: Carbon dioxide 0-5000ppm, methane 0-5000ppm;

6.5 Resolution: 1ppm;

6.6 Data acquisition cycle: 5 minutes;

6.7 Probe dehumidification protection system: Yes;

6.8 Gas chromatograph: Can be used in conjunction;

6.9 Anaerobic biodegradation experiment: Can be done;
7. Software control system:

7.1 Software control system with independent intellectual property rights;

7.2 The software collects data and can generate real-time data curves;

7.3 Carrier system: win7/8/10 professional edition operating system;

7.4 Data storage method: Real-time storage during the experiment;

7.5 Has a cloud platform, which can remotely view data.

7.6 Running persistence: Can work continuously for more than 6 months;

V. Product Configuration

Serial Number

Name

Quantity

Unit

Remarks

1

Host

1

Unit

 

2

Reaction bottle

12

Piece

 

3

Decarbonization system

1

Set

 

4

Condenser

12

Piece

 

5

Condensing device

1

Set

 

6

Dehumidifying bottle

12

Piece

 

7

Connecting hose

1

Set

 

8

Software

1

Set

 

9

Random files

1

Set

 

Hydroponic infrared biodegradation instrument