OM7000A

品牌:Ohkura
型号:OM7000A
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Quantity
-
+
Stock:
1
Brand:
Ohkura
Model:
OM7000A
Product description
Parameters

  一、product uses:

  1. It can be used for the detection of biodegradation by activated sludge method, meeting the requirements of GB / t19276-1;

  2. It can be used for soil biodegradation detection, meeting the requirements of GB / t22047-2008;

  3. It can be used to detect the biodegradability of plastics in seawater / sandy sediment, ISO 18830;

  4. Meet the international standards ISO 14851, ISO 17556;

  5. Rapid biodegradability test of chemicals, GB / T 21801, GB / T 21802, GB / T 21803;

  6. Meet the requirements of oecd301c, oecd301f, oecd302c, ec-partc4, is05815-1:2003;

  7. Meet the requirements of OECD, EEC, ASTM, BBA, ISO, MITI test research;

  8. It can be used for the determination of bod3, BOD5, bod7, bod28, bod42, etc;

  9. Microbial respiration test;

  10. Microbial breeding experiment;

  二、 Product features:

  1. Accurate detection system: measuring oxygen consumption through electrical signals;

  2. No need to dilute the sample: the maximum detection limit can reach 1000 ppm;

  3. Data processing software: a set of software can control 8 devices to work at the same time;

  4. Good data repeatability: at present, the data repeatability of similar instruments in the world is the best;

  5. Continuous electrolytic oxygen supply: add new copper sulfate electrolyte after the electrolyte is used up;

  6. Precise temperature control: the temperature setting range is 5-40 ℃, and the temperature regulation accuracy is ± 0.1 ℃;

  7. Channel number: each instrument includes 6 detection channels;

  8. Two way mixing system: mixing speed, time and direction can be set by oneself;

  9. Dual data output system: computer processing with special software and LCD.

  三、Product principle:

  The microorganism consumes oxygen in the culture bottle to produce carbon dioxide. The carbon dioxide is absorbed by quicklime. The pressure of the culture bottle is reduced, resulting in a pressure difference between the two sides of the pressure gauge, which leads to the connection of the electrolysis circuit. The copper sulfate solution in the electrolytic bottle produces oxygen by electrolysis, which is added to the culture bottle, so that the pressure in the culture bottle gradually returns to the initial level. The coulometer can accurately monitor the electric quantity of the electrolytic bottle and calculate the oxygen consumption. The ratio of the actual oxygen consumption to the theoretical oxygen consumption is the biodegradation rate of the tested sample.

  四、Technicalparameters:    

  1. Continuous dynamic oxygen supply system

  1.1 channel: at most 6 channels are tested at the same time;

  1.2 oxygen supply mode: oxygen is produced by electrolysis of copper sulfate;

  1.3 the internal liquid of the electrolytic bottle: copper sulfate solution;

  1.4 pressure gauge: sensitivity 9.806 PA, internal copper sulfate solution;

  1.5 material of mounting frame: propylene;

  1.6 electrolytic bottle: capacity 500 ml, material: hard glass;

  1.7 electrode: platinum (positive), copper (negative);

  1.8 culture bottle: 500 ml (for 300 ml sample Culture), material: hard glass;

  1.9 air bottle material: hard glass;

  1.10 agitator material: fluorinated resin;

  2. Constant temperature culture system

  2.1 set temperature range: 5-40 ℃, step 0.1 ℃;

  2.2 temperature accuracy: ± 0.1 ℃;

  2.3 control mode: SSR drive, on / off control;

  2.4 environmental conditions: 5-30 ℃, 35-85% RH;

  2.5 - temperature regulator: digital temperature controller ec5502r00020, - 150 ℃ ~ 150 ℃, PT100;

  2.6 refrigerators: Reciprocating sports refrigerators 2500W;

  2.7 safety device: Hydraulic thermostat (the setting temperature of anti overheating device is about 60 ℃);

  2.8 refrigerator protection: overload relay, automatic recovery pressure switch;

  3. Magnetic stirring system

  3.1 voltage: 100 V; power: 3 W;

  3.2 standard specification: clockwise rotation speed: 540 RPM (50 Hz) / 650 RPM (60 Hz);

  3.3 option 1: clockwise rotation; speed: 70-800 RPM adjustable;

  3.4 option 2: bidirectional rotation; rotational speed: 540 RPM (50 Hz) / 650 RPM (60 Hz);

  4. Detection system

  4.1. The measurement is more accurate by converting the charge movement into oxygen consumption;

  4.2 Sensitivity: 0.2 ppm;

  4.3 measurement range: 0-1000 ppm;

  4.4 temperature probe: PT100;

  4.5 alarm output: 2-point output, contact capacity, 3A / 250VAC, 3A / 30VDC;

  4.6 alarm function: abnormal electrolytic current, abnormal integral speed, continuous on / off alarm of pressure gauge;

  4.7 communication: Ethernet, transmission type: 10Base-T;

  5. Software control system

  5.1 software control system with independent property rights;

  5.2 the software is connected to the host computer through the unique ARCNET device;

  5.3 a set of software can control up to 8 devices at the same time;

  5.4 the software collects data and generates real-time data curve.

  

  五、Standard configuration:

  1. One main engine;

  2. A set of continuous oxygen supply device;

  3. A set of software.

We could not find any corresponding parameters, please add them to the properties table
Previous